Back to News
Tags:Engineering & Integration

Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage

Wireless temperature & humidity monitoring with iNut: dedicated sensors, data sent over WiFi Mesh, automatic relay/fan/valve control by threshold, Email/Telegram alerts, real-time monitoring on the iNut app & SCADA dashboard. Fast install, no wiring, solar-powered outdoors.

Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage
WIRELESS TEMP & HUMIDITY

Mount the sensor, power it on, and the data starts flowing: iNut measures temperature and humidity in real time, sends it over wireless WiFi Mesh, automatically triggers fans – relays – valves based on thresholds, and sends instant alerts via Email/Telegram when safe limits are exceeded.

No wall drilling, no wiring, no one needs to stand watch — from a single storage room to an entire factory complex.

Wireless temperature and humidity monitoring with iNut

In cold storage, pharmaceutical warehouses, server rooms, livestock farms, or production plants, just a few hours of temperature or humidity drifting outside the safe range can ruin goods, kill a batch, or halt a production line. Yet the common way to monitor is still walking around with a thermometer to log readings each shift, or installing costly, tangled signal cabling — data that's fragmented, not real-time, and usually only reveals a problem after it's too late.

Wireless temperature and humidity monitoring solves exactly that bottleneck: let the sensor measure continuously, let the data fly back over the air, and let the system handle alerts and control instead of a person standing watch. With iNut, you mount the device on the wall, power it up, configure it in the app, and you're done — no signal cabling, no drilling, and adding another measuring point takes just minutes.

Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage — visual 1Technical diagram for Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage. iNut WiFi Mesh Point 1 Point 2 Point 3 Point 4 ALL MEASURING POINTS, ONE PLATFORM — NO WIRES
01

Dedicated temperature & humidity sensors — accurate at every point

Every accurate alert starts with an accurate measurement. iNut's temperature and humidity sensors deliver high accuracy and fast response, measuring both temperature (°C) and relative humidity (%RH) simultaneously at each location — in cold storage, curing rooms, server rooms, or outdoors. Data is standardized and tagged by measuring point, so you know exactly where a reading is drifting out of range.

MEASURE TEMPERATURE °C + HUMIDITY %RH SIMULTANEOUSLY

Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage — visual 2Technical diagram for Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage. Temperature 28.6°C Humidity 62 %RH iNutdata standardizationTemp & humidity sensor unit
02

WiFi Mesh connectivity — fast install, no wiring

This is the solution's real selling point: iNut WiFi Mesh nodes automatically pair up, with distant nodes relaying through nearer ones to blanket the whole area with coverage — through walls, across multiple rooms, down long corridors — without a single meter of signal cable. In places that are hard to wire, like cold storage, basements, or outdoor sites, the iNut RS485 / WiFi Mesh solution just works once mounted; adding another measuring point is as simple as adding a new node, and the network picks it up automatically.

NODE RELAYS TO NODE → WIRELESS COVERAGE → GATEWAY

Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage — visual 3Technical diagram for Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage. Node A Node B Node C Node D iNutGatewayUplink 4G
03

Automatic threshold-based control

A measurement only matters if you can act on it. Set the thresholds once: temperature too high → fan/AC turns on; humidity too high → dehumidifier/ventilation runs; humidity too low → misting valve opens; once conditions are met, it switches off automatically. At the edge layer, iNut PC runs the logic and switches relays – valves – fans right on site, while iNut Muro handles microclimate control for places that need very stable temperature and humidity. No one needs to stand by to flip switches.

THRESHOLD EXCEEDED → RELAY CLOSES → FAN RUNS → TEMPERATURE DROPS

Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage — visual 4Technical diagram for Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage. Measured temperature threshold iNut PCcompare thresholdrun logic Relay Cooling fan
04

Instant alerts via Email & Telegram

Temperature and humidity incidents tend to happen when no one's watching — the middle of the night, a day off. iNut PC monitors continuously, and whenever a value exceeds or drops below a threshold or the sensor signal is lost, the system immediately pushes an alert via Email and Telegram with the measuring point, value, and timestamp — even in areas with only 4G coverage, thanks to the gateway's uplink. You find out about a problem the moment it starts, instead of discovering ruined goods the next morning.

THRESHOLD EXCEEDED → INSTANT EMAIL · TELEGRAM ALERT

Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage — visual 5Technical diagram for Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage. threshold Real-time temp & humidity chart Threshold exceeded! Email Telegram
05

Real-time monitoring on the iNut dashboard & app

All measuring points appear on a single screen: real-time temperature and humidity charts, a status map for each room, and history for lookup and report exports. With the iNut app you view data and change thresholds remotely right from your phone; iNut Platform (self-hosted cloud) builds a SCADA-style dashboard for the whole system, paired with iNut Datalogger for long-term data storage. Data is transparent, and whoever's on duty can grasp the situation in seconds.

Remote temperature and humidity monitoring on the iNut app
Monitor every temperature and humidity measuring point in real time right from the iNut app.

REAL-TIME DASHBOARD — MULTIPLE MEASURING POINTS AT ONCE

Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage — visual 6Technical diagram for Wireless Temperature & Humidity Monitoring with iNut — Fast Install, No Wiring, WiFi Mesh Coverage. iNut Platform · SCADA TemperatureHumidity iNut app 28°62%
06

Field deployment — solar-powered, remote configuration

In places without stable grid power — outdoor stations, remote warehouses, riverside farms — iNut devices still run reliably on solar power and wireless data transmission. Install once and the data flows back automatically; every parameter and threshold can be adjusted remotely via the iNut app without a site visit. For systems that already have control cabinets or measuring instruments, iNut RS485 and iNut OPC (OPC UA/Modbus/XML-DA) gateways help pull that data into the same platform.

iNut RS485 cabinet solar-powered at an outdoor monitoring station
Outdoor iNut cabinet, solar-powered — no grid power, no wiring.
Remote iNut RS485 configuration on the iNut app
Configure & change thresholds remotely right from the iNut app.

// Quick specs

MEASURES
Temperature °C · Humidity %RH
CONNECTIVITY
WiFi Mesh · RS485 · 4G
AUTOMATION
Relay · valve · fan by threshold
ALERTS
Email · Telegram · real-time
MONITORING
iNut app · SCADA dashboard
POWER
Solar power · outdoor

What do you gain from wireless temperature & humidity monitoring?

Extremely fast install

Mount the sensor, power it on, configure in the app — no wall drilling, no signal cabling.

Wide coverage

WiFi Mesh relays through multiple nodes, passing through walls to cover areas that are hard to wire.

Timely alerts

Exceeding a threshold or losing signal triggers an instant Email/Telegram alert — know early, resolve quickly.

Proactive and transparent

Automatic threshold-based control with stored history for lookup — less spoilage, easy to verify.

Temperature and humidity haven't changed — only the way we watch them has

The air in a warehouse, a curing room, or a server room still rises and falls the same as ever; what's new is that we can see every change through real-time data and let the system alert and act right on time — instead of logging numbers by hand and guessing. Without the tangle of signal cables, expanding your measuring points is as easy as adding one more node to the wall.

Right now, is there a spot in your facility quietly drifting out of range — that no one has noticed yet?

Share this article

Send it to a teammate or keep the link for later

Share on FacebookShare on TwitterShare on LinkedInShare via WhatsAppShare on ZaloSend by email