Back to News
Tags:Factories & Automation

iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together

iNut OPC is industrial OPC Server software running on a Windows PC: it gathers data from Modbus, MQTT… and simultaneously serves OPC UA (4840), Modbus TCP (5020) and OPC XML-DA (8895). Includes an OPC UA Browser, real-time diagnostics, Excel/JSON export and secure FTP/FTPS file sync.

iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together
INDUSTRIAL OPC SERVER SOFTWARE

iNut OPC — bringing every protocol together under one OPC standard

Installed on a single Windows PC, iNut OPC talks to devices over Modbus, MQTT… and simultaneously serves data to SCADA/MES via OPC UA, Modbus TCP and OPC XML-DA — with real-time diagnostics, Excel/JSON export and secure FTP/FTPS file sync.

One piece of software, three servers, every connection — already running 24/7 at real factories.

iNut OPC industrial OPC Server software

A typical factory is packed with all kinds of devices: PLCs speaking Modbus RTU/TCP, sensors pushing MQTT, digital meters that differ from brand to brand. Meanwhile SCADA, MES or the production operating system want to read data through one common standard — usually OPC. Without a "translation station" in the middle, integration turns into a tangle of wires and patchwork code.

iNut OPC sits exactly at that junction: a gateway software running on a PC, collecting from every protocol below and emitting the OPC standard above — so the rest of the system only has to "speak one language".

iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together — visual 1Technical diagram for iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together. IN: EVERY PROTOCOL — OUT: OPC STANDARD Modbus RTU Modbus TCP MQTT OPC UA Modbus Server OPC XML-DA iNut OPCOPC
01

All connections in one project

A familiar tree-style interface: each channel is a data source (Modbus TCP, MQTT bridge, simulator…), with devices and tags underneath. Add/edit quickly, filter by name/address, and import – export Excel/JSON to duplicate configurations across machines in just seconds.

iNut OPC dashboard listing connection channels
iNut OPC dashboard — project tree on the left, connection table (driver, host, port) and Excel/JSON export on the right.

DEVICES → iNut OPC (PC) → SCADA / MES

iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together — visual 2Technical diagram for iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together. PLC · Sensors Modbus/MQTT iNut OPCOPC OPC UA SCADA · MES
02

Mapping tags to OPC in just a few clicks

Declare each tag once — Modbus address, data type, scan cycle — and iNut OPC automatically exposes it as a standard OPC node. For example, the Temperature tag (Modbus 40001, INT16, 1000ms scan) instantly appears at MODBUS TCP.PLC 1.Temperature with its value and "Good" quality.

Temperature tag mapped to OPC DA, Good quality
PLC 1's tag table — address 40001, INT16 type, 1000ms scan, mapped straight to OPC DA, Good quality.

1 MODBUS TAG → 1 STANDARD OPC NODE

iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together — visual 3Technical diagram for iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together. Modbus 40001INT16 · 1000ms scanSlave ID 1 OPCiNut OPC PLC 1.Temperature10Good
03

Three servers running in parallel

From the same data set, iNut OPC simultaneously serves three interfaces: OPC UA (port 4840), Modbus TCP Server (port 5020) and OPC XML-DA (port 8895). Whatever SCADA a customer uses, it can connect — no lock-in to a single standard. The Diagnostics screen shows the status of each server, client count and live tag values.

iNut OPC diagnostics: OPC UA 4840, Modbus TCP 5020, XML-DA 8895 running
Real-time diagnostics — three servers "Running", client count, word order, and live tag values updating over time.

3 PORTS OPEN IN PARALLEL — ANY SCADA CAN CONNECT

iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together — visual 4Technical diagram for iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together. OPC UA4840Running Modbus TCP5020Running OPC XML-DA8895Running
04

OPC UA Browser — check right inside the software

No external tools needed: enter the endpoint opc.tcp://…:4840 and click Connect to browse the server's entire address space, inspecting nodes and values. Very handy for on-site acceptance testing before handing off to SCADA.

iNut OPC OPC UA Browser
Built-in OPC UA Browser — browse the address space directly at the endpoint opc.tcp://localhost:4840.
05

FTP File Transfer — secure sync & backup

iNut OPC ships with a two-way FTP/FTPS file transfer mechanism to automatically back up and synchronize projects/data between the machine at the factory and the central server. The core is designed "safety first": Ed25519-signed manifests against tampering, atomic file writes with SHA-256 checks, hot SQLite backups that don't disrupt the running database, bandwidth limiting and an audit security-check engine.

iNut OPC FTP File Transfer syncing files between PC and FTP
FTP File Transfer — create a profile to automatically upload/download/sync files between the PC and the FTP server.

TWO-WAY SYNC — SIGNING, HASH CHECKING, ATOMIC WRITES

iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together — visual 5Technical diagram for iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together. Factory PC FTP / FTPS Ed25519 · SHA-256 · Atomic write
06

Already running in real factories

iNut OPC isn't a paper demo: the software is already running 24/7 at multiple factories, including the Pá Chiến and Mường Hung hydropower plants — where stability and fault recovery are mission-critical requirements.

ONE CENTER — MANY FACTORIES

iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together — visual 6Technical diagram for iNut OPC — Industrial OPC Server Software: Bringing Every Protocol Together. Centermonitoring Pá Chiến Mường Hung Other plant Other plant

// Quick specs

INPUT PROTOCOLS
Modbus RTU/TCP · MQTT
OUTPUT SERVERS
OPC UA 4840 · Modbus 5020 · XML-DA 8895
TOOLS
OPC UA Browser · Diagnostics · Log
DATA
Import/Export Excel · JSON
BACKUP
FTP/FTPS two-way · Ed25519 · audit
PLATFORM
Windows PC · Linux HMI
LICENSE
10,000,000 VND / Windows machine
FIELD-PROVEN
Running at Pá Chiến, Mường Hung…

Why choose iNut OPC?

One gateway for everything

Gathers Modbus, MQTT… and emits OPC UA/Modbus/XML-DA — cutting out patchwork integration code.

On-site acceptance testing

OPC UA Browser & real-time diagnostics let you check instantly, no external tools needed.

Data safety

Two-way FTP sync with signing, hash checking, atomic writes and hot backups — no worries about loss or corruption.

Field-proven

Running 24/7 at real factories, with clear per-machine licensing cost.

Amid a jungle of protocols, you need one gateway

Every device brand has its own standard, yet the production operating system just wants one common voice. iNut OPC quietly builds that bridge — turning the chaos below into a clean, standardized, trustworthy data stream above.

How many languages is your factory speaking — and who's translating for them?

Share this article

Send it to a teammate or keep the link for later

Share on FacebookShare on TwitterShare on LinkedInShare via WhatsAppShare on ZaloSend by email